Performance testing provides a measure of A/C system operating efficiency. A manifold pressure gauge set is used to determine both high and low pressures in the refrigeration system. The desired pressure readings will vary according to temperature. Use temperature/pressure charts as a guide to determine the proper pressures. At the same time, a thermometer is used to determine air discharge temperature in the passenger compartment.
SERVICE VALVES
System service valves provide the attachment point for the manifold pressure gauge set. They are located in the low and high sides of most A/C systems. Two basic types of service valves were used on R-12 systems: stem and Schrader. R-134a systems have quick-connect fittings. The fittings for the gauges are connected to the system’s fittings. The gauge’s fitting has a knob that is turned in the clockwise direction to open the valve. No refrigerant should leak out when the gauge set is connected.
 |
| A thermometer is used to determine air discharge temperature in the passenger compartment. |
Stem Valves. The stem valve was sometimes used on twocylinder reciprocating-piston compressors. The service valves are mounted on the compressor head. These valves can be used to